Precision test for the Sensirion SHT35 humidity sensor

condensed window
Weather monitoring: measuring wind at a festival site
Choose the right flow meter for your next water project
How to measure Dew Point and Wet Bulb temperature
Precision test for the Sensirion SHT35 humidity sensor
Installing a weather station on caravans, holiday homes or recreational vehicles
L'effet du vent sur la mesure des particules
Connecter un capteur Watermark au cloud
Watermark ou SMT100 : teneur en eau volumétrique ou tension hydrique du sol ?
Collecte et interprétation connectées de données géotechniques
6 tips for making the most of your cold room
Temperature registration for HACCP
Quickly tackle the 7 principles of HACCP
6 lists to quickly get started with HACCP
Surveillance de la teneur en eau du sol des cultures
Surveillance des murs végétalisés : pourquoi votre jardin vertical a besoin de capteurs connectés
Comment Reporter est-il alimenté ?
Tempêtes et échafaudages : les stations météorologiques pour renforcer la sécurité des chantiers de construction
Capteur de mesure du niveau d'eau dans un conteneur ou un puits
Sumaq, fan de la simplicité de Reporter
Protection des fleurs d'arbres fruitiers contre le gel
Alerte aux intempéries sur votre chantier
Système de surveillance et d'alerte en temps réel contre le gel
Prévenir Pseudomonas syringae dans les arbres fruitiers
Stockage frigorifique des fleurs coupées avec surveillance de la température
Module de capteurs IoT avec tracker GPS
Quelle est la température idéale d'une chambre froide ?
Utilisations de l'API Crodeon
Une station météorologique avec API
4 facteurs à envisager avant d'acheter un capteur de température avec API
Une station météorologique avec capteur de niveau d'eau pour marina ou port
VITO aide à améliorer la rétention et l'utilisation de l'eau en Flandre
Pourquoi nous fabriquons en Belgique
Rénovation du pont d'Haringvliet : une station météorologique pour les chantiers
Quelle est la température idéale pour une salle serveur ?
Surveillance environnementale facile pour salle serveur
Steen Vastgoed et Reporter, un duo à toute épreuve !
FKT et Reporter : match en chambre froide
Une station météorologique avec plusieurs capteurs
Un détecteur de panne de courant pour votre chantier
Mesure combinée de la pression et de la température
Using a weather station on your construction site
Analyse du climat des toitures
Une irrigation durable avec un système de surveillance de la consommation d'eau
Surveillance de toits verts
Industrial odour monitoring with a weather station
L'impact du niveau des nappes phréatiques sur les fissures et les dégradations des bâtiments
Appareil IoT 4G et alimenté à l'énergie solaire : Reporter révolutionne la surveillance à distance
Housing requirements for a poultry farm: the complete guide
Surveillance du traitement thermique dans les conteneurs de fret
How to prevent and detect a barn fire in a pig pen

We recently tested and documented the precision of the SHT35 T/RH sensor from Sensirion. In this article we explain the results of our tests.

The SHT35 is the high-end version of the SHT3x series that Sensirion calls the new industry standard in humidity sensing. In our case we’re talking about the SHT35-DIS-F version of the SHT35, which includes an on-chip PTFE foil membrane that allows for sensor use under harsh environmental conditions.

What does the datasheet say?

The datasheet of the SHT35 lists the accuracy of all versions of the sensor. Please note that the accuracy is not the same thing as the precision of a sensor. More about this later.

The SHT35-DIS-F offers the highest accuracy of all: 1,5% humidity @0-80% RH) and 0,1°C temperature (@20-60 °C), which is quite impressive. Let’s see if this is the case if we compare multiple of these sensors in real life.

sensirion sht35 specs

Results of our tests

We tested the precision of 6 of these sensors over a period of 12 hours. The goal was to compare the values with the average of all measurements and see if the deviation was within the accuracy limits.

A few words about the form factor of the sensors. We used these RH sensors from Crodeon, which are enclosed in a radiation shield suited for outdoor use. All sensors were connected to our Reporter, a wireless gateway with gsm connection to the cloud.

€499

After 12 hours we downloaded the data from the Crodeon Dashboard to Excel. This is where the interesting part started. The following graph shows the temperature readings of our 6 sensors on an interval of 5 minutes. Reporter can handle more intense intervals up to 30 seconds but for this test we thought 5 minutes was sufficient.

sht35 temperature precision

As you can see in the data, almost all of the readings fall within the accuracy limits of -0,1°C and + 0,1°C as claimed in the datasheet.

Now it’s time to investigate the humidity readings. The SHT35 is one of the most accurate humidity sensors on the market. It’s really hard to find this kind of sensors with an accuracy of +/-1,5%RH or better. The following graph did not disappoint us.

sht35 humidity precision

Precision versus accuracy

The attentive readers will surely point out that we haven’t really investigated the accuracy of our sensor. That’s right. As explained by Wikipedia, in a set of measurements, accuracy is closeness of the measurements to a specific value, while precision is the closeness of the measurements to each other.

A next quality control would be to test these humidity sensors in a calibrated environment to see how they compare to real world values, which must be measured by a primary of secondary calibrated standard. This is something we will blog about in the near future.

Conclusion

As you can see, we were very satisfied with the performance of the SHT35 digital TRH sensor. The precision is outstanding and we have high hopes for the accuracy as well. We will continue to use this sensor in our research projects for Smart Agriculture, Smart Construction, industry, Smart Indoor Climate, and Smart Food.

Measuring relative humidity can be especially useful when it comes to cut flower preservation, farming mealworms, cold storage of onions or potatoes, monitoring paper archives, monitoring dew point and wet bulb temperatures, or in construction projects to monitor dew point for glue applicationRH in curing concrete, or preventing concrete decay in existing structures.

Retour au blog

Des questions?

Appelez-nous au +32474097705 ou utilisez le formulaire de contact

1 de 4
  • Demo laptop

    Démo en ligne en direct

    Créez un compte gratuit sur Crodeon Dashboard et regardez une démo en direct pour découvrir son fonctionnement.

    Regarder la démo 
  • person

    Parlez à un représentant

    Prenez rendez-vous avec Jonathan, notre responsable commercial, pour en savoir plus sur cette solution.

    Planifier un appel 
  • phone email

    Contactez-nous

    Pour un partenariat, une demande de distribution, ou toute autre question, n'hésitez pas à nous contacter !

    Nous contacter